The Treatment of Proximal Humerus Fracture Using Internal Fixation with Fixed-angle Plates
Patrick Ziegler1, Sven Maier, Ulrich Stöckle
1BG Hospital Tübingen, University Clinic for Trauma and Reconstructive Surgery, University of Tübingen, Germany; Center for Musculoskeletal Surgery, Charité University Medical Center Berlin, Germany; Center for Bone and Joint Surgery, Kronprinzenbau Hospital, Reutlingen, Germany; BG Hospital Murnau, Murnau, Germany.
Background:
Implants made of various types of material can be used for the internal fixation of fractures. Carbon fiber reinforced polyetheretherketone (CFR-PEEK) is a radiolucent material that may have advantageous handling properties compared with titanium implants.
Methods:
Seventy-six patients with proximal humerus fractures requiring surgery were randomized to receive a fixed-angle plate made out of either titanium or CFR- PEEK. To measure the functional outcome, the DASH score (Disabilities of Arm, Shoulder, and Hand; primary endpoint), the Simple Shoulder Test (SST), and the Oxford Shoulder Score (OSS) were determined in 63 patients at 6 weeks, 12 weeks, and 6 months after surgery, accompanied at each time point by radiological evaluation.
Results:
Both groups displayed improvement in DASH scores 6 months after surgery (CFR-PEEK: 27.5 ± 20.5; titanium: 28.5 ± 17.9; p = 0.82). Sensitivity analysis with multiple imputations confirmed this result (27.4 ± 19.2 versus 28.5 ± 16.6). The OSS and SST scores were likewise improved in both groups. All patients displayed full bony consolidation 12 weeks after surgery. In no case was material failure, secondary dislocation, or screw perforation seen. No difference was seen in the maintenance of postoperative reposition between the CFR-PEEK group and the titanium group.
Conclusion:
The internal fixation of proximal humerus fractures with either CFR-PEEK or titanium led to clinical improvement 6 months after surgery. No clinical or radiological difference in outcomes was seen between the two groups. Because of the study design, however, the equivalence of the two interventions was not con- clusively demonstrated; a non-inferiority study would have been needed for this purpose.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Humerus