Analysis for Alpha-Pyrrolidinovalerophenone and Its 2-Oxo-PVP Metabolite in Plasma by Liquid Chromatography-Tandem
David M Andrenyak1, David E Moody1, Jonathan M Crites1
1Center for Human Toxicology, Department of Pharmacology and Toxicology, University of Utah, 30 S. 2000 E. Rm 3861, Salt Lake City, UT 84108, USA.
Abstract:
Alpha-pyrrolidinovalerophenone (alpha-PVP), a novel psychoactive substance, has widespread recreational use. This with interest in its pharmacological effects creates a need for methods that measure alpha-PVP concentrations. We therefore developed a LC-MS/MS method that can quantitate alpha-PVP and 2-oxo-PVP in rat plasma using a 0.1-mL sample volume. Addition of internal standards (2.5 ng/mL alpha-PVP-d8/2-oxo-PVP-d6) was followed by liquid-liquid extraction with 1-chlorobutane:acetonitrile (4:1), evaporation and reconstitution with 0.1% formic acid. Extracts were analyzed by LC-MS/MS using an Agilent 1100 HPLC and a Thermo Scientific TSQ Quantum Access MS/MS, with a YMC ODS-AQ, 50 mm × 2 mm, 3 μm column. The mobile phase was 0.1% formic acid:acetonitrile gradient at a 0.2-mL/minute flow rate with positive ion electrospray. SRM was used for the analysis with transitions: alpha-PVP, 232 → 91; alpha-PVP-d8, 240 → 91; 2-oxo-PVP, 246 → 91; 2-oxo-PVP-d6, 252 → 91. Alpha-PVP and 2-oxo-PVP eluted at 6.4 and 8.9 min. Calibrators range from 0.25 to 500 ng/mL. Accuracy and precision evaluated quality control samples prepared at 0.75, 10 and 400 ng/mL. The intra-assay evaluation also included the 0.25-ng/mL LOQs prepared in six different blank plasma sources. The intra-assay accuracy ranged from 88.9 to 117.8% of the target, and the intra-assay precision ranged from 0.9 to 16.0%. The inter-assay accuracy ranged from 98.7 to 110.7% of the target, and the inter-assay precision ranged from 4.5 to 12.0%. Extraction recovery was at least 52% for alpha-PVP and 67% for 2-oxo-PVP. Ionization recoveries were at least 64% for alpha-PVP and 82% for 2-oxo-PVP. These losses did not adversely affect assay performance. Alpha-PVP and 2-oxo-PVP controls were stable at room temperature for up to 24 h and frozen for at least 36 days. Alpha-PVP and 2-oxo-PVP were also stable in processed samples (extracts) stored at room temperature for at least 24 days. The procedure was used to analyze rat plasma samples from a pharmacokinetic study.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Therapeutic Drug Monitoring: Drug Analysis Methods
