Abstract:
Accurate assessment of burn wound depth and the associated healing potential is vital in determining the need for surgical treatment in burns. Infrared thermography measures the temperature of the burn wound noninvasively, thereby providing indirect information on its blood flow. Previous research demonstrated that a small, low-priced, handheld thermal imager has an excellent reliability, but a moderate validity for measuring burn wound healing potential. A new and more sensitive version of this convenient device has become available. The aim of this study was to evaluate the validity of thermography for measuring burn wound healing potential, compared to Laser Doppler Imaging (LDI) as a reference standard. Thermal images and LDI scans were obtained from burn wounds between 2 and 5 days postburn. Temperature differences between burned and nonburned skin (ΔT) were calculated. To evaluate validity, ΔT values were compared to the healing potential categories assessed by LDI. Two receiver operating characteristic curves were created and two ΔT cutoff values were calculated to illustrate the ability to discriminate between burn wounds that heal in a time period of less than 14 days, between 14 and 21 days, and more than 21 days. Between June and October 2018, 43 burn wounds in 32 patients were measured. ΔT cutoff values of 0.6°C (sensitivity 68%, specificity 95%) and -2.3°C (sensitivity 30%, specificity 95%) were calculated to discriminate between burn wounds that heal in <14 and ≥14 days, and burn wound that heal in ≤21 and >21 days, respectively. This study shows a good validity of the feasible thermal imager for the assessment of burn wound healing potential. Therefore, we consider it a promising technique to be used for triage in local hospitals and general practices, and as a valuable addition to clinical evaluation in burn centers.
Related Concept Videos
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...