A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
A novel fiber-optic pressure sensor device for measuring variceal pressure
Xi Wang1, Huixian Li1, Jing Wang1
1Department of Gastroenterology, Anhui Geriatric Institute, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui 230022, P.R. China.
Abstract:
It has been reported that variceal pressure can predict the occurrence of variceal bleeding. However, the majority of methods presently used to measure variceal pressure are either invasive or inconvenient. In the present study, a fiber-optic pressure sensor was constructed to detect variceal pressure. The prospective study focused on the in vitro accuracy of a fiber-optic pressure sensor and investigated the clinical reliability and feasibility of this method. The fiber-optic pressure sensor covered a pressure-sensitive probe containing a fiber-optic pressure sensor and a workstation to record the pressure tracing. It was hypothesized that the endoscopic fiber-optic pressure sensor can effectively predict the risk of variceal bleeding. To test this hypothesis, 80 patients who suffered from cirrhosis and who had a history of variceal bleeding were included in the present study. The fiber-optic pressure sensor was guided through the biopsy channel using an endoscope in the patient cohort. Transjugular intrahepatic stent-shunt (TIPS) was subsequently performed within 24 h after measuring variceal pressure. A comparison of the results of the 80 patients was made between variceal pressure measured by the endoscopic fiber-optic pressure sensor and the portal pressure gradient (PPG) measured by a TIPS. The variceal pressure measurements with the fiber-optic pressure sensor were technically satisfactory in 78 patients. The results indicated that there was a linear correlation between the variceal pressure measured by the endoscopic fiber-optic pressure sensor and the PPG (r=0.940, P<0.001). These observations suggest that the fiber-optic pressure sensor is an accurate and feasible measurement technique. Therefore, the results of the present study indicate that the endoscopic fiber-optic pressure sensor is effective in predicting the risk of variceal bleeding.
More Related Videos
09:04Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pressure Gauges
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.