Don't go chasing artificial waterfalls: Artificial line limits and cascading failures in power grids
J Bourne1, A O'Sullivan1, E Arcaute2
1UCL Energy Institute, University College London, Gower Street, London WC1E 6BT, United Kingdom.
Abstract:
Research on cascading failures in power-transmission networks requires detailed data on the capacity of individual transmission lines. However, these data are often unavailable to researchers. Consequently, line limits are often modeled by assuming that they are proportional to some average load. However, there is scarce research to support this assumption as being realistic. In this paper, we analyze the proportional loading (PL) approach and compare it to two linear models that use voltage and initial power flow as variables and are trained on the line limits of a real power network that we have access to. We compare these artificial line-limit methods using four tests: the ability to model true line limits, the damage done during an attack, the order in which edges are lost, and accuracy ranking the relative performance of different attack strategies. We find that the linear models are the top-performing method or are close to the top in all the tests we perform. In comparison, the tolerance value that produces the best PL limits changes depending on the test. The PL approach was a particularly poor fit when the line tolerance was less than two, which is the most commonly used value range in cascading failure research. We also find indications that the accuracy of modeling line limits does not indicate how well a model will represent grid collapse. The findings of this paper provide an understanding of the weaknesses of the PL approach and offer an alternative method of line-limit modeling.
Related Concept Videos
Maximum Power Flow and Line Loadability
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Power System Three-Phase Short Circuits
Fast Decoupled and DC Powerflow