A lock-in amplifier modeling recovery method to extract the surface nuclear magnetic resonance signal from residual
Yang Zhang1, Zhenyang Yu1, Yue Li1
1Key Laboratory for Geophysical Instrument of Ministry of Education, Jilin University, Changchun 130061, China and College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130061, China.
Abstract:
Surface nuclear magnetic resonance (SNMR) could provide direct insights for hydrological investigations but is often limited because of its low signal-to-noise ratio. Many types of residual noise remain after denoising procedures, including despiking, power harmonic noise cancellation, and random noise attenuation. This residual noise prevents the detection of valid signals, especially in strong noise environments, such as cities and industrial areas. In this work, a lock-in amplifier modeling recovery (LIAMR) method is proposed for extracting SNMR signals from high-level residual noise after denoising. The desired SNMR signals can be extracted directly by establishing a model of the SNMR signal passing through the lock-in amplifier and then transforming mathematically the output of the amplifier. The performance of the proposed method is tested on synthetic SNMR signals under varied average relaxation times, simulation noise at different levels, and field noise. Experiment results show that LIAMR can obtain good estimations of SNMR signal parameters with residual noise. Moreover, the proposed method can provide more precise parameters compared with traditional signal extraction methods. LIAMR provides theoretical support for the application of SNMR technology in strong noise environments.
More Related Videos
10:28Measuring Interactions of Globular and Filamentous Proteins by Nuclear Magnetic Resonance Spectroscopy NMR and Microscale Thermophoresis MST
Published on: November 2, 2018
09:26Functional Magnetic Resonance Spectroscopy at 7 T in the Rat Barrel Cortex During Whisker Activation
Published on: February 8, 2019
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Magnetic Resonance
Atomic Nuclei: Nuclear Relaxation Processes
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...