Related Experiment Video
Updated: Jan 2, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Changes in pharyngeal collapsibility and genioglossus reflex responses to negative pressure during the respiratory
Amal M Osman1,2,3,4, Jayne C Carberry1,2,3, Simon C Gandevia1,2
1Neuroscience Research Australia (NeuRA), Sydney, NSW, Australia.
Key Points:
Impaired pharyngeal anatomy and increased airway collapsibility is a major cause of obstructive sleep apnoea (OSA) and a mediator of its severity. Upper airway reflexes to changes in airway pressure provide important protection against airway closure. This study shows increased pharyngeal collapsibility and attenuated genioglossus reflex responses during expiration in people with OSA.
Abstract:
Upper airway collapse contributes to obstructive sleep apnoea (OSA) pathogenesis. Pharyngeal dilator muscle activity varies throughout the respiratory cycle and may contribute to dynamic changes in pharyngeal collapsibility. However, whether upper airway collapsibility and reflex responses to changes in airway pressure vary throughout the respiratory cycle in OSA is unclear. Thus, this study quantified differences in upper airway collapsibility and genioglossus electromyographic (EMG) activity and reflex responses during different phases of the respiratory cycle. Twelve middle-aged people with OSA (2 female) were fitted with standard polysomnography equipment: a nasal mask, pneumotachograph, two fine-wire intramuscular electrodes into the genioglossus, and a pressure catheter positioned at the epiglottis and a second at the choanae (the collapsible portion of the upper airway). At least 20 brief (∼250 ms) pressure pulses (∼-11 cmH2 O at the mask) were delivered every 2-10 breaths during four conditions: (1) early inspiration, (2) mid-inspiration, (3) early expiration, and (4) mid-expiration. Mean baseline genioglossus EMG activity 100 ms prior to pulse delivery and genioglossus reflex responses were quantified for each condition. The upper airway collapsibility index (UACI), quantified as 100 × (nadir choanal - epiglottic pressure)/nadir choanal pressure during negative pressure pulses, varied throughout the respiratory cycle (early inspiration = 43 ± 25%, mid-inspiration = 29 ± 19%, early expiration = 83 ± 19% and mid-expiration = 95 ± 11% (mean ± SD) P < 0.01). Genioglossus EMG activity was lower during expiration (e.g. mid-expiration vs. mid-inspiration = 76 ± 23 vs. 127 ± 41% of early-inspiration, P < 0.001). Similarly, genioglossus reflex excitation was delayed (39 ± 11 vs. 23 ± 7 ms, P < 0.001) and reflex excitation amplitude attenuated during mid-expiration versus early inspiration (209 ± 36 vs. 286 ± 80%, P = 0.009). These findings may provide insight into the physiological mechanisms of pharyngeal collapse in OSA.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Pulmonary Cycle: Exhalation
Respiratory Volumes and Capacities I
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

