Related Experiment Video
Updated: Jan 2, 2026

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Simultaneous quantification of humic acid-water and silanized glass-water partition constants for PCBs, PCDDs and
Veronika J Schacht1, Murray Manning1, Sharon C Grant1
1Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland, 4102, Australia.
Abstract:
Super-hydrophobic organic contaminants (SHOCs) such as polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and octachlorodibenzofuran (OCDF) can sorb to dissolved hydrophobic materials including humic acids (HAs), enhancing their apparent aqueous solubility and potentially resulting in increased groundwater contamination and offsite transport. To manage risks associated with transport of and contamination by SHOCs, modelling approaches incorporating partitioning data, i.e. dissolved organic carbon-water partition constants (KDOC), are necessary. Measurement of KDOC can however be compromised by SHOC sorption to glassware surfaces leading to an overestimation of experimental values resulting in larger KDOC. A method for simultaneous derivation of KDOC and glass-water partition constants (KGW) is described. It involves a mass balance approach combined with HA as a co-solvent at various concentrations and accounts for SHOC losses to silanized glassware. Measured log KDOC values ranged from 5.28 to 7.64 for tetra- to decachlorinated PCBs, 6.67 to 7.93 for tetra- to octachlorinated PCDDs and 8.20 for OCDF. These data were linear functions of log KOW and consistent with relationships reported for more polar compounds. Log KGW (mm3 mm-2) values (1.62 to 4.06 for PCBs, 2.96 to 3.90 for PCDDs, 3.77 for OCDF) were one order of magnitude greater compared to literature PCB borosilicate glass-water partition constants. Techniques such as those presented in this work present simple, versatile means to provide prediction of the SHOC proportion remaining in aqueous solutions after loss to glassware that was inversely related to container surface area/volume ratio and log KOW in our study.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
08:57VacuSIP, an Improved InEx Method for In Situ Measurement of Particulate and Dissolved Compounds Processed by Active Suspension Feeders
Published on: August 3, 2016