Value of Index Beat in Evaluating Left Ventricular Systolic and Diastolic Function in Patients with Atrial
Ling-Yun Kong1, Lan-Lan Sun2, Ling-Ling Chen1
1Cardiology Department, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University. Changping District, Beijing, China.
Insights
Assessing left ventricular (LV) function in atrial fibrillation (AF) is challenging. The index beat method for systolic mitral annular velocity (s’) and pre-index beat E/e’ ratio effectively evaluate LV function using echocardiography in AF patients.
Area of Science:
- Cardiology
- Echocardiography
- Cardiac Physiology
Background:
- Atrial fibrillation (AF) complicates echocardiographic assessment of left ventricular (LV) function.
- Traditional methods for LV function evaluation may be less reliable in the presence of irregular heart rhythms like AF.
- The index beat method offers a potential alternative for assessing cardiac function during AF.
Purpose of the Study:
- To evaluate the utility of the index beat method for assessing LV function in patients with AF.
- To compare the accuracy of the index beat method with established averaging techniques.
- To determine the optimal Doppler-derived parameters for LV function assessment during AF.
Main Methods:
- Utilized dual pulsed wave Doppler to simultaneously measure peak early diastolic mitral inflow velocity (E) and mitral annular velocities (diastolic e', systolic s') beat-to-beat.
- Assessed patients diagnosed with atrial fibrillation.
- Compared index beat measurements of s' and E/e' ratios against mean values obtained through averaging methods.
Main Results:
- The index beat systolic mitral annular velocity (s') demonstrated strong correlation with mean values (r=0.96 for septal, r=0.92 for lateral wall).
- The E/e' ratio calculated at the pre-index beat showed superior correlation with mean values (r=0.88 for septal, r=0.97 for lateral wall) compared to the index beat cycle.
- Both parameters showed statistically significant correlations (p<0.000).
Conclusions:
- The index beat method, particularly for s', is a valuable tool for assessing LV systolic function in AF.
- The E/e' ratio derived from the pre-index beat is a reliable indicator of LV diastolic function in AF patients.
- These findings support the use of specific index beat and pre-index beat Doppler parameters for accurate LV function assessment in AF.
Abstract:
Atrial fibrillation (AF) poses challenges in use of the echocardiogram to assess left ventricular (LV) function. The index beat method has been found to agree well with the average method. We aimed to assess the value of the index beat method in evaluation of LV function using the dual pulsed wave Doppler technique. Peak early diastolic mitral inflow velocity (E) and diastolic (e') and systolic (s') mitral annulus velocity were simultaneously obtained and measured beat-to-beat in patients with AF. The index beat s' exhibited the best correlation (r = 0.96 and 0.92, respectively, for septal and lateral wall, both p values = 0.000) with the mean, while E/e' at the pre-index beat, rather than at the index beat-initiated cycle, had the best correlation with the mean (r = 0.88 for septal and 0.97 for lateral wall, both p values = 0.000).
More Related Videos
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Dysrhythmias V: Evaluating Dysrhythmias
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...