Related Experiment Video
Updated: Jan 2, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Two Distinct Types of Sweat Profile in Healthy Subjects While Exercising at Constant Power Output Measured by a
Dong-Hoon Choi1, Grant Kitchen1, Ji Soo Kim2
1Institute for Nanobiotechnology, John Hopkins University, 3400 North Charles Street, Baltimore, Maryland, 21218, USA.
Abstract:
Wearable sweat sensors have enabled real-time monitoring of sweat profiles (sweat concentration versus time) and could enable monitoring of electrolyte loss during exercise or for individuals working in extreme environments. To assess the feasibility of using a wearable sweat chloride sensor for real-time monitoring of individuals during exercise, we recorded and analyzed the sweat profiles of 50 healthy subjects while spinning at 75 Watts for 1 hour. The measured sweat chloride concentrations were in the range from 2.9-34 mM. The sweat profiles showed two distinct sweat responses: Type 1 (single plateau) and Type 2 (multiple plateaus). Subjects with Type 2 profiles had higher sweat chloride concentration and weight loss, higher maximum heart rate, and larger changes in heart rate and rating of perceived exertion during the trial compared to subjects with Type 1 profiles. To assess the influence of level of effort, we recorded sweat profiles for five subjects at 75 W, 100 W, and 125 W. While all five subjects showed Type 1 sweat profiles at 75 W, four of the subjects had Type 2 profiles at 125 W, showing an increase in sweat chloride with exercise intensity. Finally, we show that sweat profiles along with other physiological parameters can be used to predict fluid loss.
Related Concept Videos
Accessory Structures of the Skin: Sweat Glands
Sweat glands are classified as merocrine glands; that is, the secretions are excreted by exocytosis through a duct without affecting the cells of the gland. There...
Special considerations while measuring pulse
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes

