Related Experiment Video
Updated: Jan 2, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
Published on: December 30, 2025
A new frequency domain passive acoustic mapping method using passive Hilbert beamforming to reduce the computational
Pilsu Kim1, Jae Hee Song2, Tai-Kyong Song1
1Department of Electronic Engineering, Sogang University, Seoul 04107, Republic of Korea.
Abstract:
Passive acoustic mapping (PAM) is the current state-of-the-art imaging tool for monitoring cavitation activity during focused ultrasound therapy such as blood-brain barrier opening. However, PAM incurs huge computational complexity. To address this issue, frequency-domain PAM (FD-PAM) was proposed. Nevertheless, FD-PAM still requires a large number of fast Fourier transforms (FFTs) to produce the frequency components utilized for cavitation monitoring with PAM. Hence, in this paper, we proposes a frequency domain PAM method using passive Hilbert beamforming (PHB-PAM), which can significantly reduce the number of input samples for FFT by down-sampling the analytic signal of the received RF samples at each channel at a rate equal to the bandwidth of the frequency components of interest. The experimental results show that the proposed PHB-PAM provides comparable image quality to that of FD-PAM (correlation coefficient > 0.98). Additionally, the study experimentally verifies that the pre-processing block for generating the decimated analytic signal and FFT in PHB-PAM can be realized using lesser logic resources than FFT in FD-PAM when implemented in an FPGA. Especially, with 128-fold decimation, PHB-PAM reduces the amount of LUTs and DSP slices to implement the pre-processing block by 72.16% and 53.4%, respectively, compared to those of FD-PAM, which allows the 64-channel implementation of the pre-processing block in a low-cost single FPGA. Finally, a hardware-efficient architecture for the pre-processing block of PHB-PAM is described, which can be implemented by replacing the two lowpass filters of an off-the-shelf analog front-end component for ultrasound imaging with a pair of band-pass filters. If PHB-PAM is realized using such a component, it can truly minimize the computational complexity of FD-PAM.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
09:10The Frequency Domain Thermoreflectance Technique for Thermal Property Measurements
Published on: December 5, 2025
Related Concept Videos
Fast Fourier Transform
The computational efficiency of the FFT becomes...
Properties of Fourier Transform I
In radio broadcasting, multiple audio signals often need to be transmitted simultaneously. The Fourier...
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2....
Discrete Fourier Transform
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Basic signals of Fourier Transform
The sinc function, defined as sinc(x) = sin(πx)/(πx), is particularly notable for its symmetry and behavior at...