Related Experiment Video
Updated: Jan 2, 2026

Continuous Hydrologic and Water Quality Monitoring of Vernal Ponds
Published on: November 13, 2017
Dataset for a wireless sensor network based drinking-water quality monitoring and notification system
Mhambi Phila Philadephian Sithole1, Nnamdi I Nwulu1, Eustace M Dogo1
1Department of Electrical and Electronic Engineering Science, University of Johannesburg, South Africa.
Abstract:
This paper presents the collected experimental data for water quality monitoring which was conducted in ten experiments by using five different common sources of water contaminants namely soil, salt, washing powder, chlorine and vinegar and their combination. The data were collected indoors at room temperature during the day for several days using sensors that measure pH, turbidity, flow rate, and conductivity in water. The water consumption risk (CR) was calculated as deviation based on the water quality parameters standards proposed by the World Health Organisation (WHO) and the South African Department of Water Affairs (DWA), with respect to the sensor measurement readings obtained. While the error measurements were calculated based on the expected parameter measurement per conducted experiment and repeated for 26 measurements. Pure tap water was the benchmark of water safe for human consumption. The first five experiments were performed by introducing each contaminant into the water and thereafter, two contaminants in the sixth experiment and their additions until all different contaminants were experimented at once in the last experiment.
Related Concept Videos
Testing Water Quality
Quality of Water