Related Experiment Video
Updated: Jan 2, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Identification of Suvorexant in Blood Using LC-MS-MS: Important Considerations for Matrix Effects and Quantitative
Britni Skillman1, Sarah Kerrigan1
1Department of Forensic Science, Sam Houston State University, 1003 Bowers Blvd., Huntsville TX, 77341, USA.
Abstract:
Suvorexant (Belsomra®) is a novel dual orexin receptor antagonist used for the treatment of insomnia. The prevalence of suvorexant in forensic samples is relatively unknown, which demonstrates the need for robust analytical assays for the detection of this sedative hypnotic in forensic toxicology laboratories. In this study, suvorexant was isolated from whole blood using a simple acidic/neutral liquid-liquid extraction followed by analysis by liquid chromatography tandem mass spectrometry (LC-MS/MS). Matrix effects were evaluated qualitatively and quantitatively using various extraction solvents, proprietary lipid clean-up devices and source conditions. The method was validated in terms of limit of detection, limit of quantitation, precision, bias, calibration model, carryover, matrix effects and drug interferences. Electrospray is a competitive ionization process whereby compounds in the droplet compete for a limited number of charged sites at the surface. As such, it is capacity-limited, and LC-MS-based techniques must be carefully evaluated to ensure that matrix effects or coeluting drugs do not impact quantitative assay performance. In this report, we describe efforts to ameliorate such effects in the absence of an isotopically labeled internal standard. Matrix effects are highly variable and heavily dependent on the physico-chemical properties of the substance. Although there is no universal solution to their resolution, conditions at the electrospray interface can mitigate these issues. Using this approach, the LC-MS/MS assay was fully validated and limits of detection and quantitation of 0.1 and 0.5 ng/mL suvorexant were achieved in blood.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
MALDI-TOF Mass Spectrometry
Therapeutic Drug Monitoring: Drug Analysis Methods