Evaluation of SUV normalized by lean body mass (SUL) in 68Ga-PSMA11 PET/CT: a bi-centric analysis
Andrei Gafita1, Jeremie Calais2, Charlott Franz3
1Department of Nuclear Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany. andrei.gafita@tum.de.
Introduction:
The aim of this analysis was to investigate whether the standardized uptake value (SUV) normalized by lean body mass (SUL) is a more appropriate quantitative parameter compared to the commonly used SUV normalized by patient's weight in 68Ga-PSMA11 PET/CT.
Material And Methods:
68Ga-PSMA11 PET/CT scans of 121 patients with prostate cancer from two institutions were evaluated. Liver SUV was measured within a 3-cm volume-of-interest (VOI) in the right hepatic lobe and corrected for lean body mass using the Janmahasatian formula. SUV and SUL repeatability between baseline and follow-up scans of the same patients were assessed.
Results:
SUV was significantly positively correlated with body weight (r = 0.35, p = 0.02). In contrast, SUL was not correlated with body weight (r = 0.23, p = 0.07). No significant differences were found between baseline and follow-up scan (p = 0.52).
Conclusion:
The Janmahasatian formula annuls the positive correlations between SUV and body weight, suggesting that SUL is preferable to SUV for quantitative analyses of 68Ga-PSMA11 PET/CT scans.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...