Related Experiment Video
Updated: Jan 2, 2026

Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Determination of Lead Elemental Concentration and Isotopic Ratios in Coal Ash and Coal Fly Ash Reference Materials
Chaofeng Li1,2, Huiqian Wu1,2,3, Xuance Wang4,5
1State Key Laboratory of Lithospheric Evolution, Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing 100029, China.
Abstract:
The rapid expansion of coal-fired power plants around the world has produced a huge volume of toxic elements associated with combustion residues such as coal fly ash (CFA) and coal ash (CA), which pose great threats to the global environment. It is therefore crucial for environmental science to monitor the migration and emission pathway of toxic elements such as CFA and CA. Lead isotopes have proved to be powerful tracers capable of dealing with this issue. Unfortunately, up to now, few high precision lead isotope data of CFA and CA certified reference materials (CRMs) determined by using the double spike technique have been reported. Hence, to facilitate the application of lead isotopes in environmental science, it is indispensable and urgent to determine a suite of high precision Pb isotope ratios and Pb elemental contents for CFA and CA CRMs. Here, we measured lead isotope ratios from four CFA and CA CRMs using thermal ionization mass spectrometry (TIMS) combined with the 204Pb-207Pb double spike method. Lead isotope ratios values of CRMs (GBW11124, GBW08401, GBW11125d, and JCFA-1) covered wide variation ranges from 17.993 to 19.228 for 206Pb/204Pb, from 15.513 to 15.675 for 207Pb/204Pb, and from 38.184 to 39.067 for 208Pb/204Pb. Lead isotope ratios of these CRMs, except for GBW11124, show good external reproducibility (2 RSD, n = 8), which is better than 0.05% for 206Pb/204Pb and 207Pb/204Pb, 0.07% for 208Pb/204Pb, 0.04% for 206Pb/207Pb, and 0.05% for 208Pb/206Pb. The Pb concentrations of these CRMs were determined using 207Pb single spike method. The reproducibility (1 RSD, n = 4) of Pb elemental content was <0.60%. This indicates the distribution of Pb elements in these CRMs is homogeneous. With the exception of GBW11124, the suite of CRMs can be used for determining CFA and CA matrix composition for quality control of Pb isotope analyses.
More Related Videos
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Atomization Methods
Mass Spectrometry: Isotope Effect

