Related Experiment Video
Updated: Jan 2, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Comparative Analysis of Dentinal Crack Formation Following Root Canal Instrumentation with Hand K-Flex Files,
John Jacob1, Midhun Paul2, Bilu Sara3
1Department of Conservative Dentistry and Endodontics, St. Gregorios Dental College, Ernakulam, Kerala, India, Phone: +91 7594852829,
Aim:
To evaluate and compare in vitro the dentinal crack formation in root canal dentin after root canal instrumentation with hand K-Flex files, ProTaper Next, and self-adjusting engine-driven files.
Materials And Methods:
Ninety-two human mandibular first molar teeth were randomly divided into four groups (n = 23) as per the instrumentation protocol: group I-unprepared teeth (control); group II-hand K-Flex files (Sybron Endo); group III-ProTaper Next X1 and X2 (Dentsply Maillefer); group IV-self-adjusting file (ReDent Nova, Israel). All the roots were sectioned perpendicular to the long axis of the tooth at 9 mm, 6 mm, and 3 mm from the apex and thereby obtaining sixty-nine samples, which were then subjected to a stereomicroscopic examination for detection of dentinal cracks. Statistical analyses were done using the Chi-square test with SPSS (version 19), and p value was set at p < 0.05.
Results:
Statistically significant differences were seen between the instrumented groups. No dentinal cracks were found in the unprepared roots and those prepared with hand K-Flex files (0/23). Self-adjusting-file-instrumented group showed significantly less incidence of crack formation when compared to the ProTaper Next group with p = 0.001.
Conclusion:
Self-adjusting file is an efficient engine-driven NiTi instrument for root canal instrumentation with the least occurrence of crack formation in the root canal dentin compared to the ProTaper Next system.
Clinical Significance:
The introduction of NiTi rotary file systems has metamorphosed the endodontic treatment by their better cutting efficiency and cleaning potentiality. Yet, evidenced-based clinical studies are to be conducted on the incidence of microfractures that can lead to vertical root fractures, which will be produced irrespective of the motion kinematics and design feature and thereby compromising the clinical maintenance of the endodontically treated teeth.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024