Related Experiment Video
Updated: Jan 2, 2026

Fabrication of Three-dimensional Paper-based Microfluidic Devices for Immunoassays
Published on: March 9, 2017
Microfluidic Time-Delay Valve Mechanism on Paper-Based Devices for Automated Competitive ELISA
Yu-Ting Lai1, Chia-Hsin Tsai2, Ju-Chun Hsu2
1Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, Taipei 10016, Taiwan.
Abstract:
Paper-based technologies have been drawing increasing attentions in the biosensor field due to their economical, ecofriendly, and easy-to-fabricate features. In this paper, we present a time-delay valve mechanism to automate a series of procedures for conducting competitive enzyme-linked immunosorbent assay (ELISA) on a paper-based device. The mechanism employs a controllable time-delay valve, which has surfactants to dissolve the hydrophobic barriers, in a fluid pathway. The valves can regulate the liquid and sequentially deliver the sample flow for automating ELISA procedures in microchannels. Competitive ELISA is achieved in a single step once the sample, or small molecule pesticide (e.g., Imidacloprid), is applied onto the paper-based device with a comparable sensitivity to plate-based competitive ELISA. The results further demonstrate the appositeness of using paper-based devices with the valve designs for on-the-go ELISA detection in agriculture and biomedical applications.