Related Experiment Video
Updated: Jan 2, 2026

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Bond Strength of Individually Formed and Prefabricated Fiber-reinforced Composite Posts
Purpose:
To investigate the micro push-out bond strength of individually formed (everStick Post) and prefabricated (GC Fiber Post) fiber-reinforced composite (FRC) posts cemented with three different types of self-adhesive composite cements.
Materials And Methods:
Forty-two single-rooted human teeth were decoronated, endodontically treated, and had post spaces prepared for everStick Post (n = 21) or GC Fiber Post (n = 21). The teeth were randomly divided into three subgroups (n = 7), and posts were cemented either with G-CEM LinkAce (GC), SpeedCEM (Ivoclar Vivadent) or RelyX U200 (3M Oral Care). Specimens were then perpendicularly sectioned and divided at the cementoenamel junction into two root levels: coronal or apical. A micro push-out test was performed using an 0.8-mm-wide stainless steel plunger. Bond strength was calculated in MPa by dividing the fracture load (N) by the bonded surface area (mm2). Log-transformed data was statistically analyzed using factorial ANOVA and Tukey's post-hoc test (α < 0.05). Fracture modes were determined employing a stereomicroscope, and differences were evaluated using a likelihood ratio test and Pearson's chi-squared test. Specimens were also observed using SEM.
Results:
Bond strengths were significantly affected by both post type and root level (p < 0.05), but not by self-adhesive cement (p > 0.05). Fracture types showed a significantly higher prevalence of adhesive fractures at the apical level, with all fractures starting at the cement-dentin interface.
Conclusion:
Individually formed FRC posts demonstrated greater bond strength than their prefabricated FRC counterparts. The apical level of the luted posts yielded lower bond strengths than the coronal level. Failures were predominantly adhesive at the cement-dentin interface.
Related Concept Videos
Fiber Reinforced Concrete
Bonding and Strength of Aggregate
Reinforcements in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...

