Related Experiment Video
Updated: Jul 10, 2026

Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
Determination of human erythropoietin by radioimmunoassay. Method and clinical data
1Dept. of Internal Medicine and Hematology, Gentofte University Hospital, Hellerup, Denmark.
Abstract:
A sensitive competitive radioimmunoassay for the determination of circulating human erythropoietin (Epo) is presented. This RIA of human Epo is founded on the extensive application of a recombinant protein approach. Thus, highly purified recombinant human Epo is employed both as a tracer, immunogen and occasionally as standard in the RIA. The lower limit of detection is approximately 8 mU/ml and well below the mean value of Epo in normal individuals (25.6 +/- 6.6 mU/ml). The intra- and interassay variation are 6.3 and 9.2%, respectively. The documentation of consistent alterations in Epo plasma levels of selected categories of anemic patients establishes the clinical relevance of the immunoassay. The radioimmunoassay of human Epo fulfills reasonable requirements of a clinical routine analysis in terms of both specificity, sensitivity and practicability.