Development and validation of a mass spectrometric method to determine the identity of rituximab based on its
Francisco C Perdomo-Abúndez1, Luis Vallejo-Castillo1, Said Vázquez-Leyva1
1Unidad de Desarrollo e Investigación en Bioprocesos (UDIBI), Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Ciudad de México 11340, Mexico.
Abstract:
Analytical methods have been considered the "eyes" for development, characterization and batch releasing of biotherapeutics over the past 40 years. One of the most powerful analytical platform for biotherapeutic analysis is mass spectrometry coupled to liquid chromatography (LC-MS). Due to its wide flexibility and instrumental configurations, LC-MS can determine different physicochemical attributes of proteins, e.g. molecular mass, primary sequence, and posttranslational modifications. Intact molecular mass analysis of therapeutic proteins is essential to confirm their identity. Analytical methods must be validated to support drug quality information during its approval process. Although there are international guidelines that provide general information on validation of analytical methods, practical examples about the design, selection of validation attributes and acceptance criteria of identity LC-MS methods are scarce. Here, according to the recommendations of Q2R1 ICH guideline, we showcase the validation of an LC-MS-TOF method to identity rituximab by determining its intact and deglycosylated molecular mass profiles. The proposed method specifically identified the m/z profile and deconvoluted mass profile of rituximab from deglycosylated rituximab and from excipient blank (specificity) with a maximum error of 76.63 ppm (accuracy) and a maximum Relative Standard Deviation (RSD) of 0.00315% (precision). Besides, the system suitability test, which was based on the expected mass value of the mass calibrator, confirmed the reliability of the analytical results. In summary, validation showed that the proposed method is suitable for identifying rituximab based on its glycosylated (intact) and deglycosylated mass profile.
More Related Videos
09:40A Mass Spectrometry-Based Proteomics Approach for Global and High-Confidence Protein R-Methylation Analysis
Published on: April 28, 2022
07:25In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
