Related Experiment Video
Updated: Jan 2, 2026

Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Isolating the entire pulmonary venous component versus isolating the pulmonary veins for persistent atrial
Ahmed I Elbatran1,2, Mark M Gallagher1, Anthony Li1
1Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, London, UK.
Background:
The outcomes of pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) are suboptimal. The entire pulmonary venous component (PV-Comp), consisting of the pulmonary veins, their antra, and the area between the antra, provides triggers and substrate for AF. PV-Comp isolation is an alternative strategy for persistent AF ablation.
Methods:
Among 328 patients with persistent AF who underwent a first radiofrequency ablation procedure, 200 patients (PVI, n = 100; PV-Comp isolation, n = 100) were selected by propensity score matching. Both groups were followed up for 1 year.
Results:
At 6- and 12-month follow-up, atrial tachyarrhythmia (AF/atrial tachycardia) recurred in 41 and 61 patients in PVI group and 22 (P = .006) and 33 patients (P < .001) in PV-Comp isolation group, respectively. PV-Comp isolation was associated with longer mean time to recurrence (PVI: 8 months, PV-Comp isolation: 10 months, log-rank P < .001) and a lower probability of recurrence (odds ratio [OR] = 0.32; 95% confidence of interval [CI] = 0.18-0.56, P < .001), with no increase in procedural complications (PVI: 5 of 100, PV-Comp isolation: 6 of 100, P = .76). Procedure duration was longer in PV-Comp isolation group (PVI: 186 ± 42 min, PV-Comp isolation: 238 ± 44 min, P < .001), as well as fluoroscopy time (PVI: 22 ± 16 min, PV-Comp isolation: 31 ± 21 min, P = .001).
Conclusion:
PV-Comp isolation for persistent AF reduced atrial tachyarrhythmia recurrence up to 1 year compared with PVI alone. While procedure and fluoroscopy time increased, there was no difference in procedural complications.