Related Experiment Video
Updated: Jan 2, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Size-Specific Dose Estimates Based on Water-Equivalent Diameter and Effective Diameter in Computed Tomography
Jian Xu1, Xiangquan Wang2, Huawei Xiao1
1Department of Radiology, Zhejiang Provincial People's Hospital, People's Hospital of Hangzhou Medical College, Hangzhou, Zhejiang, China (mainland).
Abstract:
BACKGROUND To determine the difference in size-specific dose estimates (SSDEs), separately based on effective diameter (deff) and water equivalent diameter (dw) of the central slice of the scan range in computed tomography coronary angiography (CTCA). MATERIAL AND METHODS There were 134 patients who underwent CTCA examination, were electronically retrieved. SSDEs (SSDEdeff and SSDEdw) were calculated using 2 approaches: deff and dw. The median SSDEs and mean absolute relative difference of SSDEs were calculated. Linear regression model was used to assess the absolute relative difference of SSDEs based on the ratio of deff to dw. RESULTS The median values of SSDEdeff and SSDEdw were 18.26 mGy and 20.56 mGy, respectively (P<0.01). The former was about 10.08% smaller than the latter. The mean absolute relative difference of SSDEs was 10.48%, ranging from 0.33% to 24.16%. A considerably positive correlation was found between the absolute relative difference of SSDEs and the ratio of deff to dw (R²=0.9561, r=0.979, P<0.01). CONCLUSIONS The value of SSDEdeff was smaller by an average of about 10.08% than SSDEdw in CTCA, and the absolute relative difference increased linearly with the ratio of effective diameter to water equivalent diameter.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT