Related Experiment Video
Updated: Jan 2, 2026

Protocol of Electrochemical Test and Characterization of Aprotic Li-O2 Battery
Published on: July 12, 2016
Quantifying oxygen distortions in lithium-rich transition-metal-oxide cathodes using ABF STEM
E Liberti1, J G Lozano1, M A Pérez Osorio1
1Department of Materials, University of Oxford, Parks Road OX1 3PH, UK.
Abstract:
Lithium-rich cathodes can store excess charge beyond the transition metal redox capacity by participation of oxygen in reversible anionic redox reactions. Although these processes are crucial for achieving high energy densities, their structural origins are not yet fully understood. Here, we explore the use of annular bright-field (ABF) imaging in scanning transmission electron microscopy (STEM) to measure oxygen distortions in charged Li1.2Ni0.2Mn0.6O2. We show that ABF STEM data can provide positional accuracies below 20 pm but this is restricted to cases where no specimen mistilt is present, and only for a range of thicknesses above 3.5 nm. The reliability of these measurements is compromised even when the experimental and post-processing designs are optimised for accuracy and precision, indicating that extreme care must be taken when attempting to quantify distortions in these materials.
More Related Videos
10:03Characterization of Electrode Materials for Lithium Ion and Sodium Ion Batteries Using Synchrotron Radiation Techniques
Published on: November 11, 2013
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway