On-Line Coupling of Simultaneous Distillation-Extraction Using the Likens-Nickerson Apparatus with Gas Chromatography
Pei-Han Liao1,2, Hui-Hsien Yang1,2, Pei-Chi Wu1,2
1Department of Chemistry , National Tsing Hua University , 101, Section 2, Kuang-Fu Road , Hsinchu 30013 , Taiwan.
Abstract:
Simultaneous distillation-extraction (SDE) using the Likens-Nickerson apparatus is a convenient technique used to isolate volatile organic compounds (VOCs) from complex liquid matrices. The technique combines steam distillation with solvent extraction. While analytical extractions are normally followed by off-line separation/detection, it is advantageous to couple extractions on-line with separation and detection systems that are employed in the same analytical workflow. Here, we have coupled the Likens-Nickerson apparatus on-line with a gas chromatograph hyphenated with a mass spectrometer. For that purpose, we have devised an automated liquid transfer setup comprising a peristaltic pump, control unit, customized transfer vial with a drain port, and an autosampler arm to deliver liquid extract aliquots at defined time points. The on-line SDE-GC/MS system enables one to record real-time extraction profiles. These profiles reveal extraction kinetics of various VOCs present in the extracted samples. The data sets were fitted with the first order kinetic equation to obtain numeric values characterizing the extraction process (rate constants ranging from 0.21 to 0.01 min-1 for the ethyl esters from C6 to C19). A comparison of on-line and off-line results reveals that the on-line system is more dependable, while the off-line analysis leads to artifacts. To demonstrate the operation of the on-line SDE-GC/MS system, we performed analyses of selected real samples (beer). The real-time data sets revealed extraction kinetics for VOCs present in these samples. The devised extraction-analysis system allows the analysts to make an evidence-based decision on the extraction time for different groups of analytes in order to maximize extraction yield and minimize analyte losses.
More Related Videos
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Detectors-II
