Related Experiment Video
Updated: Jan 2, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Patient perceptions of ambulatory blood pressure monitoring testing, tolerability, accessibility, and expense
Jennifer S Ringrose1,2, Raj Bapuji3, Wade Coutinho4
1Department of Medicine, University of Alberta, Edmonton, AB, Canada.
Abstract:
Use of 24-hour ambulatory blood pressure monitoring is strongly endorsed by contemporary hypertension guidelines. The objective of this study was to assess patient perceptions of ambulatory blood pressure testing, tolerability, accessibility, and expense. A convenience sample of 50, consenting patients undergoing ambulatory blood pressure monitoring at the University of Alberta Hypertension Clinic in Edmonton, Canada was studied. A 16-item structured questionnaire was administered in person or electronically. Questions regarding the tolerability of ambulatory monitoring were evaluated using a 5-point Likert scale and wait times, expenditures, and willingness to pay were evaluated by direct questioning. Mean age was 53.1 ± 15.4 years, 32 (64%) were female, and 23 (46%) were employed. Mean 24-hour ambulatory BP was 134 ± 12/79 ± 8 mmHg. Ambulatory monitoring caused discomfort in 40 (80%) patients and disturbed sleep in 39 (78%). Forty-one (82%) patients perceived that the home (vs pharmacy, primary care clinic, and speciality care clinic) would be the easiest venue to access future testing. On average, patients waited 27.3 ± 23.7 days for testing; they felt that a wait time of 21.3 ± 12.3 days was appropriate. Mean time taken off work was 8.6 ± 10.8 hours. Twelve (24%) patients indicated that they would be willing to pay out-of-pocket to undergo testing sooner, at a mean expenditure of $120 ± 69. Nineteen (62%) patients were willing to buy a monitor and felt that a mean purchase cost of $125 ± 89 was appropriate. These findings extend current knowledge of patient perceptions of ambulatory monitoring and may help to refine and optimize future delivery of this essential test.
More Related Videos
07:13Digital Home-Monitoring of Patients after Kidney Transplantation: The MACCS Platform
Published on: April 12, 2021
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...