Related Experiment Video
Updated: Jan 2, 2026

Author Spotlight: Integrating High-Resolution Intravital Imaging and MRI to Enhance Stereotactic Body Radiation Therapy Planning
Published on: April 12, 2024
Assessment of microvessel perfusion of pituitary adenomas: a feasibility study using turbo spin-echo-based intravoxel
Kiyohisa Kamimura1, Masanori Nakajo1, Tomohide Yoneyama1
1Department of Radiology, Graduate School of Medical and Dental Sciences, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8544, Japan.
Objectives:
To evaluate the feasibility of assessment of microvessel perfusion of pituitary adenomas with intravoxel incoherent motion (IVIM) imaging using single-shot turbo spin-echo-based diffusion-weighted imaging (SS-TSE-DWI).
Methods:
We examined 51 consecutive patients with pituitary adenomas (35 non-functioning and 16 functioning) and 32 patients with normal pituitary glands using SS-TSE-DWI IVIM. The diffusion coefficient (D), the perfusion fraction (f), and the pseudo-diffusion coefficient (D*) were calculated pixel-by-pixel for each adenoma and normal pituitary gland. We also obtained the pathological microvessel area (MVA) of each adenoma. The IVIM parameters in adenomas were compared with those in normal pituitary glands using the Mann-Whitney U test. The correlation between the MVA and IVIM f of adenomas was analyzed using Spearman's rank correlation coefficient.
Results:
The mean D (× 10-3 mm2/s) in adenomas was 0.723 ± 0.253, which was significantly lower than that in normal pituitary glands (0.862 ± 0.128; p < 0.0001). The mean f (%) in adenomas was 10.74 ± 4.51, which was significantly lower than that in normal pituitary glands (13.26 ± 4.32, p = 0.0251). No significant difference was found in the mean D*. We found a significant positive correlation between MVA and f in non-functioning adenomas (ρ = 0.634, p < 0.0001) as well as in all adenomas (ρ = 0.451, p = 0.0009).
Conclusions:
Assessment of microvessel perfusion of pituitary adenomas based on SS-TSE-DWI IVIM is feasible. Compared to normal pituitary glands, pituitary adenomas were characterized by lower D and f.
Key Points:
• Assessment of microvessel perfusion of pituitary adenomas based on SS-TSE-IVIM is feasible. • SS-TSE-IVIM helps with evaluation of the vascularity of pituitary lesions. • Pituitary adenomas were characterized by lower D and f than normal pituitary glands.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...

