Standing CT of the equine head: Reducing radiation dose maintains image quality
Thomas Davies1, Cliona Skelly1, Antonella Puggioni1
1Diagnostic Imaging Department, UCD Veterinary Hospital, University College Dublin, Dublin, Ireland.
Abstract:
Multiple published studies involving computed tomographic (CT) examinations of the equine head utilise a wide range of mAs parameters for image acquisition. This prospective, experimental study assessed the effects of lowering mAs during CT image acquisition on image quality and scatter radiation on 10 cadaver equine heads. Each head was scanned three times at 300, 225, and 150 mAs, with all other scanning parameters remaining constant between series. An anthropomorphic phantom was positioned adjacent to each equine head during image acquisition, mimicking a human bystander, with an ionization chamber attached to the phantom at eye level. Each series was reconstructed using filtered back projection, using medium (H30) and high (H80) frequency reconstruction algorithms. Quantitative image quality assessment was performed by calculating signal to noise ratio (SNR) and contrast to noise ratio (CNR). Two qualitative image quality assessments were performed independently by three blinded board certified veterinary radiologists with a 4 week interval, using a visual grade analysis model adapted from peer reviewed medical literature. Ionization chamber measurements, calculated volume CT dose index (CTDIvol), and dose-length product (DLP) were recorded. Halving radiation dose during image acquisition from 300 to 150mAs resulted in comparable image quality between series. There was a statistically significant and linear relationship between mAs and scatter radiation to the bystander; halving mAs during image acquisition resulted in halving of scatter radiation. Results of this cadaveric study support the use of lower mAs settings during standing CT examinations of the equine head.
More Related Videos
11:24Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
12:09A Novel High-resolution In vivo Imaging Technique to Study the Dynamic Response of Intracranial Structures to Tumor Growth and Therapeutics
Published on: June 16, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging