Related Experiment Video
Updated: Jan 2, 2026

Ultrasonographic Assessment During Cardiopulmonary Resuscitation
Published on: October 24, 2020
A comparison of the effect of two methods of positioning the hands during basic and advanced cardiovascular life
Mohammadreza Bastami1, Parand Soliemanifard1, Roholla Hemmati2
1Department of Nursing, Faculty of Nursing and Midwifery, Ilam University of Medical Sciences, Ilam, Iran.
Abstract:
There is no agreement on how the hands are positioned in cardiopulmonary resuscitation (CPR). In this study, the effects of two methods of positioning the hands during basic and advanced cardiovascular life support on the chest compression depth are compared. In this observational simulation, the samples included 62 nursing students and emergency medicine students trained in CPR. Each student performed two interventions in both basic and advanced situations on manikins and two positions of dominant hand on non-dominant hand, and vice versa, within four weeks. At each compression, the chest compression depth was numerically expressed in centimeter. Each student was assessed individually and without feedback. The highest mean chest compression depth was related to Basic Cardiovascular Life Support (BCLS) and the position of the dominant hand on non-dominant hand (5.50 ± 0.6) and (P = 0.04). There was no statistically significant difference in the basic and advanced regression variables in men and women except in the case of Advanced Cardiovascular Life Support (ACLS) with dominant hand on non-dominant hand (P = 0.018). There was no significant difference in mean chest compression during basic and advanced cardiovascular life support in left- and right-handed individuals (P = 0.09). When the dominant hand is on the non-dominant hand, more pressure with greater depth is applied.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement