Related Experiment Video
Updated: Jan 2, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
The myopic shift associated with hyperbaric oxygen administration is reduced when using a mask delivery system
Michael H Bennett1,2,3, Cheng Fb Hui1,2, Hooi G See4
1Prince of Wales Clinical School, University of New South Wales, Sydney, Australia.
Introduction:
A temporary myopic shift is a well-recognized complication of hyperbaric oxygen treatment (HBOT). Oxidation of proteins in the crystalline lens is the likely cause. Direct exposure of the eye to hyperbaric oxygen may exacerbate the effect. Our aim was to measure the magnitude of the myopic shift over a course of HBOT when using two different methods of oxygen delivery.
Methods:
We conducted a randomised trial of oxygen delivery via hood versus oronasal mask during a course of 20 and 30 HBOT sessions. Subjective refraction was performed at baseline and after 20 and 30 sessions. We repeated these measurements at four and 12 weeks after completion of the course in those available for assessment.
Results:
We enrolled 120 patients (mean age 57.6 (SD 11.2) years; 81% male). The myopic shift was significantly greater after both 20 and 30 sessions in those patients using the hood. At 20 treatments: refractory change was -0.92 D with hood versus -0.52 D with mask, difference 0.40 D (95% CI 0.22 to 0.57, P < 0.0001); at 30 treatments: -1.25 D with hood versus -0.63 with mask, difference 0.62 D (95% CI 0.39 to 0.84, P < 0.0001). Recovery was slower and less complete in the hood group at both four and 12 weeks.
Conclusions:
Myopic shift is common following HBOT and more pronounced using a hood system than an oronasal mask. Recovery may be slower and less complete using a hood. Our data support the use of an oronasal mask in an air environment when possible.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...