Related Experiment Video
Updated: Jan 2, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Overdiscrete echo-planar spectroscopic imaging with correlated higher-order phase correction
Eduardo Coello1,2, Fatih S Hafalir1, Ralph Noeske2
1Technische Universität München, Munich, Germany.
Purpose:
To introduce a robust methodology for fast 1 H MRSI of the brain at 3T with improved SNR and reduced phase-related artifacts.
Method:
An accelerated acquisition scheme using echo-planar spectroscopic imaging (EPSI) was combined with the overdiscrete reconstruction framework. This approach enables the interleaved acquisition of a water reference scan at each phase encoding step, maximizing its correlation with the water-suppressed measurement. Moreover, a generalized high-order phase correction was incorporated into the reconstruction pipeline. The spatial-temporal phase correction term was estimated from the reference scan and interpolated to high resolution using a polynomial basis. The method was implemented at 3T and validated with phantom and in vivo experiments.
Results:
The methodology showed the elimination of spectral artifacts generated by phase disturbances and achieved mean SNR gains in vivo of 3.18 and 1.19 compared to standard reconstructions with corrections performed at nominal and high resolution, respectively. EPSI scans with interleaved water acquisition showed to be robust to system instabilities and potentially to patient motion. Moreover, phase distortions were effectively corrected in a single step, avoiding additional reference measurements and post-processing steps.
Conclusion:
The overdiscrete reconstruction framework with high-order phase correction allowed to effectively correct for distortions, related to B0 inhomogeneities, B0 drift, eddy currents, and system vibrations. Furthermore, the presented reconstruction method, combined with EPSI acquisitions, demonstrated improved measurement stability, substantial SNR enhancement, better spectral linewidth, and effective artifact removal.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...

