Related Experiment Video
Updated: Jan 2, 2026

Solid Phase 11C-Methylation, Purification and Formulation for the Production of PET Tracers
Published on: October 24, 2019
A new Centiloid method for 18F-florbetaben and 18F-flutemetamol PET without conversion to PiB
Soo Hyun Cho1,2, Yeong Sim Choe1,3,4, Hee Jin Kim1,4
1Department of Neurology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Purpose:
We developed a new method to directly calculate Centiloid (CL) units of 18F-florbetaben (FBB) and 18F-flutemetamol (FMM) without conversion to the PiB standardized uptake value ratio (SUVR).
Methods:
Paired FBB and FMM PET scans were obtained from 20 Alzheimer's disease-related cognitive impairment patients, 16 old controls, and 20 young controls. We investigated the correlations between the FBB and FMM CL units using the direct comparison of FBB-FMM CL (dcCL) method and the standard CL method and compare differences in FBB and FMM CL units between dcCL method and the standard method.
Results:
Following the conversion of FBB or FMM SUVRs into CL units, a direct relationship was formed between the FBB or FMM SUVRs and the CL units using dcCL method (FBB dcCL = 151.42 × FBB dcSUVR - 142.24 and FMM dcCL = 148.52 × FMM dcSUVR - 137.09). The FBB and FMM CL units were highly correlated in both our method (R2 = 0.97, FMM dcCL = 0.97 × FBB dcCL + 1.64) and the standard method (R2 = 0.97, FMM CLstandard = 0.79 × FBB CLstandard + 1.36). However, the CL variations between FBB and FMM were smaller when calculated by dcCL method (6.15) than when calculated by the previous method (10.22; P = 0.01).
Conclusions:
Our findings suggest that our direct comparison of FBB-FMM method, rather than the standard method, is a reasonable way to convert FBB or FMM SUVRs into CL units, at least in environments where FBB or FMM ligands are used frequently.
More Related Videos
10:04Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET