Related Experiment Video
Updated: Jan 1, 2026

Chemical Analysis of Water-accommodated Fractions of Crude Oil Spills Using TIMS-FT-ICR MS
Published on: March 3, 2017
Towards comprehensive analysis of oxygen containing organic compounds in groundwater at a crude oil spill site using
Rachel E Mohler1, Sungwoo Ahn2, Kirk O'Reilly2
1Chevron Energy Technology Company, 100 Chevron Way, Richmond, CA, 94801, USA.
Abstract:
In this study, both GC × GC-TOFMS and Orbitrap ESI-MS were used to characterize the oxygen containing organic compounds, OCOCs, present in groundwater at a site where a crude oil pipeline ruptured decades ago. This is the only side-by-side comparison of results from these two methods analyzed by the same laboratory. GC × GC-TOFMS analysis shows OCOCs identified at the crude oil-release site are consistent with, and structurally similar to, those identified at previously studied fuel release sites. Molecular structures close to the release point differ from those found downgradient, becoming less complex and with different compound classes dominating. As with the GC × GC-TOFMS, the Orbitrap revealed that the composition of OCOCs present in groundwater close to the source area was distinctly different from that seen downgradient; however, the chemical structures increased significantly in size and complexity from wells near the source to the farthest downgradient well. Investigation into this finding suggests that the presence and structures of these non-GC-able OCOCs are consistent with organic matter resulting from biosynthesis or other processes found in natural water systems and are unlikely to be intermediates (metabolites) along petroleum biodegradation pathways.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...