Related Experiment Video
Updated: Jan 1, 2026

Experimental Investigation of the Flow Structure over a Delta Wing Via Flow Visualization Methods
Published on: April 23, 2018
Overview of Different Flow Diverters and Flow Dynamics
Georgios A Maragkos1, Adam A Dmytriw1,2, Mohamed M Salem1
1Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.
Flow diverter devices for brain aneurysms are rapidly evolving, but clinical evidence lags behind. Patient-specific factors are crucial for treatment decisions due to limited comparative data on these endovascular treatments.
Area of Science:
- Neurosurgery
- Endovascular Therapy
- Biomedical Engineering
Background:
- Flow diverter technology for intracranial aneurysms has advanced rapidly over the last decade.
- The clinical evidence base for these devices has not kept pace with technological development.
- Direct comparative data against surgical clipping or other endovascular methods is lacking.
Purpose of the Study:
- To provide a comprehensive overview of available flow diverter devices.
- To summarize the existing clinical evidence for each device.
- To highlight the need for individualized patient treatment decisions.
Main Methods:
- Review of technical specifications for all currently available flow diverter devices.
- Systematic evaluation of the published clinical evidence and outcomes for each device.
- Analysis of study limitations, including retrospective designs and short follow-up periods.
Main Results:
- The Pipeline Embolization Device (PED) is the most studied, but newer data is sparse.
- No alternative flow diverters have demonstrated superiority over the PED in available studies.
- Current evidence primarily comes from retrospective studies with limited comparability.
Conclusions:
- High-quality outcome data for flow diverters is insufficient to guide device selection.
- Recommendations for choosing among different flow diversion devices cannot be reliably made.
- Treatment decisions must be individualized based on patient-specific characteristics and aneurysm factors.
More Related Videos
Related Concept Videos
Underflow Gates
Introduction to Types of Flows
Two-dimensional flow involves changes in both length and height, as seen in...
Rapidly Varying Flow
Plane Potential Flows
Uniform...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Laminar and Turbulent Flow