Related Experiment Video
Updated: Jan 1, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
A Fluorescent Sensor Based on Reversible Addition-Fragmentation Chain Transfer Polymerization for the Early Diagnosis
Wenwen Liu1, Ligang Ma2, Zhuangzhuang Guo2
1Outpatient Integrated Systems Division, People's Hospital of Zhengzhou, 33 Yellow River Road, Zhengzhou, 450053, China.
Abstract:
We propose a novel, ultrasensitive and low-cost sensor using reversible addition-fragmentation chain transfer (RAFT) polymerization as a signal amplification strategy for the detection of CYFRA 21-1 DNA fragment, a tumor marker of non-small cell lung carcinoma. The peptide nucleic acid (PNA) probes were firstly immobilized on magnetic beads (MBs) to capture the CYFRA 21-1 DNA specifically. After hybridization, CPAD was tethered to the hetero duplexes through carboxylate-Zr4+-phosphate chemistry. Subsequently, a number of fluorescent tags were introduced to the heteroduplexes through RAFT polymerization, leading to an amplification of the fluorescence signal. The sensor demonstrates a low limit of detection (LOD) of 0.02 fM. It has great selectivity with respect to base mismatch DNA, and high anti-interference ability in normal human serum. Overall findings of the study suggest that proposed sensor holds enormous potential to be used as a tool for the early-stage diagnosis of lung cancers.