Related Experiment Video
Updated: Jan 1, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
The impact of sensitive volume thickness for silicon on insulator microdosimeters in hadron therapy
D Bolst1,2, S Guatelli1, L T Tran1
1Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.
Abstract:
Compact silicon on insulator (SOI) microdosimeters have been used to characterise the radiation field of many different hadron therapy beams. SOI devices are particularly attractive in hadron therapy fields due to their spatial resolution being well suited to the sharp dose gradients at the end of the primary beam's range. Due to the small size of SOI's sensitive volumes (SVs), which are usually ∼1-10 [Formula: see text]m thick, the fabrication of these devices can present challenges which are not as common for more conventional thickness silicon devices such as silicon spectroscopy detectors. Microdosimetry is the study of the energy deposition in micrometre sized volumes representing biological sites and is a powerful approach to estimate the biological effect of radiation on the micron-scale level, in a cell. However, cell sizes vary extensively translating in different energy deposition spectra. This work studies SV thicknesses between 1 and 100 [Formula: see text]m using Geant4 and examines the impact of SV dimensions on microdosimetric quantities. The quantities studied were the frequency mean lineal energy, [Formula: see text], and the dose mean lineal energy, [Formula: see text]. Additionally the relative biological effectiveness (RBE), estimated by the microdosimetric kinetic model (MKM), is also investigated. To study the impact of the SV thickness, SOI microdosimeters were irradiated with proton, [Formula: see text] and [Formula: see text] ion beams with ranges of ∼160 mm, with the microdosimeter being set at various positions along the Bragg curve. It was found that [Formula: see text] was influenced the least in proton beams and increased for heavier ion beams. Conversely, [Formula: see text] was impacted by the SV thickness the most in proton beams and [Formula: see text] was the least. Similar to [Formula: see text], protons were impacted the most by the SV thickness when estimating the RBE using the MKM. The cause of these differences was largely due to the different densities of the delta electron track structure for the case of [Formula: see text] and the energy transferred to the medium from the primary beam for [Formula: see text].
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021