Related Experiment Video
Updated: Jan 1, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Comparison of Panoramic Radiography and Cone-Beam Computed Tomography for the Detection of Tonsilloliths
Melih Ozdede1, Gulsun Akay2, Ozge Karadag3
1Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Pamukkale University, Denizli, Turkey, melihozdede@gmail.com.
Objective:
A tonsillolith is a concretion of the tonsillar crypt. The aim of this retrospective study was to compare panoramic radiography (PR) and cone-beam computed tomography (CBCT) for the detection of tonsilloliths.
Materials And Methods:
The CBCT images of 527 patients with maxillofacial volume were evaluated retrospectively. Of these, 175 patients (81 females, 94 males; mean age 51.05 years) had unilateral or bilateral tonsilloliths. In total, 151 of them (67 females, 84 males; mean age, 51.03 years) had PR images performed in the same period and were included in the study. The PR images were examined to ascertain whether known tonsilloliths (from CBCT images) could be detected. The location (unilateral; left or right and bilateral), size, and number of the tonsilloliths were examined on both CBCT and PR images. Descriptive analysis, Spearman's rho correlation coefficient, and χ2 tests were used for the statistical analysis.
Results:
The detection rate of tonsillolith was 33.2% on CBCT images. Only 51.4% of the tonsilloliths detected on CBCT were evaluated by PR; the correlation between CBCT and PR was found to be significant (Spearman's r = 0.399, p = 0.000). PR was not adequate to detect tonsilloliths 1 mm or smaller in size. All the calcifications larger than 5 mm were detected on PR images.
Conclusion:
The results of this study showed that more than half of the tonsilloliths observed in CBCT were also detected in PR. Tonsilloliths larger than 2 mm were more likely to be detected on PR images.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Tonsillitis I: Introduction
Etiology
Three primary contributing factors have been identified.
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Tonsillitis II: Management

