This study reduced X-ray use for monitoring central lines and breathing tubes in neonatal intensive care units by over 20%. The quality improvement project successfully decreased radiograph frequency for neonates needing PICC and ETT placement.
Area of Science:
- Neonatal intensive care
- Medical imaging
- Quality improvement
Background:
- Radiographs are frequently used in neonatal intensive care units (NICUs) for monitoring the placement of peripherally inserted central catheters (PICCs) and endotracheal tubes (ETTs).
- Excessive radiograph use can lead to increased radiation exposure for vulnerable neonates.
Purpose of the Study:
- To decrease radiograph utilization for monitoring PICC and ETT placement in neonates within the NICU by 20%.
- To optimize imaging protocols and reduce unnecessary radiation exposure in a neonatal intensive care setting.
Main Methods:
- Implementation of a quality improvement (QI) project utilizing three Plan-Do-Study-Act (PDSA) cycles.
- Development and implementation of a standardized radiograph protocol including patient positioning, views, and frequency.
- Standardization of endotracheal tube (ETT) depth using Neonatal Resuscitation Program (NRP) guidelines and institution-specific criteria.
Main Results:
- Significant reduction in radiograph use per PICC day from 0.86 to 0.46 (P=0.004).
- Significant reduction in radiograph use per ETT day from 1.45 to 1.07 (P=0.002).
- Achieved a greater than 20% decrease in overall radiograph use for monitoring PICC and ETT placement.
Conclusions:
- A multidisciplinary QI project effectively reduced radiograph use for PICC and ETT monitoring in the NICU.
- The implemented strategies led to a substantial decrease in imaging frequency, contributing to reduced radiation exposure for neonates.
- The project demonstrates the successful application of QI methodologies to optimize clinical practices in the NICU.