Related Experiment Video
Updated: Jan 1, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparison of Glomerular Filtration Rate Measurement Methods between Radionuclide in vivo Scintigraphic Gates' and
Mai Hussein1, Jehan Younis1, Hosna Moustafa1
1Cairo Medical College, Cairo, Egypt.
Aim:
To correlate between the radionuclide in vitro plasma sampling method (using single and dual blood samples) and Gates' GFR measurement using Tc-99m diethylene triamine penta-acetic acid (Tc-99m DTPA) renal scintigraphy (in vivo method).
Methods:
This study included 40 renal donors (group 1) and 40 patients with obstructive uropathy (group 2). Group 1 included 22 males and 18 females with an age range from 22 to 65 years, while group 2 included 24 males and 16 females with age range 27 to 64 years. Both groups subjected to renal Scintigraphy after administration of 5 mCi 99m-Tc DTPA, GFR was calculated using Gates' method (in vivo method), then plasma sampling was acquired at 60 mins and 180 mins post-injection of the tracer, samples were counted in well counter and GFR was calculated using in vitro technique either using single plasma sample (SPSM 60 mins) or dual sample (DPSM 60 & 180 min). Additionally, GFR was measured by estimated equations based on serum creatinine.
Results:
In group 1, the mean GFR using in vivo Gates' method was 115.7 ± 29 ml/min, while using the SPSM was 100.1 ± 16.1 ml/min, and the DPSM was 100.3 ± 20.1 ml/min. In group 2, mean GFR using in vivo method was 74.1 ± 14.5 ml/min, while using in vitro SPSM it was 77.5 ± 24.9 ml/min and DPSM was 76.8 ± 24.8 ml/min. There was no significant difference between mean GFR values using in vivo and in vitro methods (single or dual samples) in group 1 and 2 (p > 0.05). There is high significant correlation between SPSM and DPSM in groups 1 and 2 (r = 0.90, r = 0.91 respectively), moderate significant correlation was found between in vivo Gates' method and in vitro SPSM in group 1 and 2 (r = 0.46 and 0.57 respectively) and moderate correlation was evident between in vivo and in vitro DPSM in both groups (r = 0.42 and 0.68 respectively). By using the DPSM as the reference standard significant high correlation was found with SPSM and significant-high moderate correlation with in vivo Gates' scintigraphic method. Conclusion: In vitro plasma sampling considered as a reliable, accurate |method for GFR calculation yet it considered relatively complex, both single and dual sample in vitro techniques showed a very high correlation, and hence SPSM can replace DPSM.
Conclusion:
Renal scintigraphy and GFR estimation using Gates' in vivo method is considered inaccurate, yet given its simplicity in performance it can still be used if corrected GFR is standardised for Egyptian population-based on studies with large numbers of patients from multiple centres.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance