Related Experiment Video
Updated: Jan 1, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
In vitro compressive strength and edge stability testing of directly repaired glass-ionomer cements
Jing Zhang1, Peter Braun2, Avijit Banerjee3,4
1Centre for Oral Clinical & Translation Sciences, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, Tower Wing, Guy's Dental Hospital, Great Maze Pond, SE1 9RT UK, UK.
Objective:
To study the repair potential of seven commercial glass-ionomer cements (GICs) using an in vitro edge compression test model.
Materials And Methods:
A total of 448 normal and 192 repaired cylindrical specimens (6 × 4 mm) were produced from 6 GICs and one resin-modified GIC. Repaired samples consisted of a base aged for 1 month before repaired by an overlying layer. All samples were matured for 1 day, 1 week, 1 month or 3 months before compression, and edge tests were performed respectively on the whole surface (compressive strength, CS) or on the edge (edge stability, ES) using a universal testing machine.
Results:
For normal specimens, Ketac Universal (KU) illustrated a significantly higher CS than other groups at all time points (p < 0.001). ES of KU was weaker than EQUIA Forte (EQF), FIX (Fuji IX) and RSC (Riva Self Cure) after 1 day, increasing after 1 week. Repaired specimens showed CS comparable to normal specimens (p > 0.05). Repaired KU significantly improved CS compared to repaired EQF and Fuji II (FII) after 1 day. No statistical difference was found in ES among these groups (p > 0.05).
Conclusions:
KU provided the fastest maturation and greatest CS and ES in both normal and repair models after short-term ageing. Repair of GICs could potentially be achieved directly onto the fractured substrate and the subsequent improved mechanical performance could be maintained for at least 3 months.
Clinical Relevance:
This study provides a potential alternative in-vitro method to assess GIC restoration failure as well as provide insight into the mechanisms of GIC restoration repair.