Improved quantification of myelin water fraction using joint sparsity of T2 * distribution
Quan Chen1, Huajun She1, Yiping P Du1
1Institute for Medical Imaging Technology, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Background:
Myelin water fraction (MWF) can be quantified with analysis of the T2 * distribution, whereas deducing the T2 * spectrum from several echoes is an underdetermined and ill-posed problem.
Purpose:
To improve the quantification of myelin water content by using nonnegative jointly sparse (NNJS) optimization.
Study Type:
Prospective.
Subjects:
Nine healthy subjects.
Field Strength/Sequence:
3T, multiecho gradient echo.
Assessment:
The results of NNJS were compared with that of the nonnegative least square (NNLS)-based algorithms. Simulated models with varied MWF at different noise levels were used to evaluate the accuracy of estimations. In human data, the MWF values of different regions were compared with previous studies and the coefficient of variation (COV) was used to assess the spatial coherence.
Statistical Test:
Paired t-test.
Results:
In simulation, the relative errors of MWF obtained from synthesized data with signal-to-noise ratio (SNR) at 500, 200, 150, and 100 were 0.08, 0.09, 0.10, and 0.12 for NNJS, 0.29, 0.43, 0.48, and 0.53 for regularized NNLS (rNNLS), and 0.19, 0.24, 0.25, and 0.26 for spatially-regularized NNLS (srNNLS). In human data, the mean values of MWF produced by NNJS in different regions were consistent with previous studies. Compared with the NNLS-based algorithms, lower COVs generated by NNJS were observed in genu, forceps minor, forceps major, and internal capsule, which were 0.44 ± 0.08, 0.48 ± 0.07, 0.46 ± 0.03, and 0.48 ± 0.09 in NNJS, 0.88 ± 0.28, 0.96 ± 0.18, 0.72 ± 0.03, and 0.85 ± 0.15 in rNNLS, and 0.56 ± 0.17, 0.64 ± 0.14, 0.50 ± 0.04 and 0.58 ± 0.13 in srNNLS.
Data Conclusion:
Quantitative results of both simulated and human data show that NNJS provides more plausible estimation than the NNLS-based algorithms. Visual advantages of NNJS in spatial consistency can be confirmed by the comparative COV index. The proposed algorithm might improve the quantification of myelin water content.
Level Of Evidence:
2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;52:146-158.
Related Concept Videos
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...