Related Experiment Video
Updated: Jan 1, 2026

Evaluation of Microbial Safety of Dairies using Bacterial Proteomic Profiling via MALDI Approach
Published on: October 7, 2025
Bacterial identification by lipid profiling using liquid atmospheric pressure matrix-assisted laser
Sophie E Lellman1, Rainer Cramer1
1Department of Chemistry, University of Reading, Whiteknights, Reading, UK.
Abstract:
Background In recent years, mass spectrometry (MS) has been applied to clinical microbial biotyping, exploiting the speed of matrix-assisted laser desorption/ionization (MALDI) in recording microbe-specific MS profiles. More recently, liquid atmospheric pressure (AP) MALDI has been shown to produce extremely stable ion flux from homogenous samples and 'electrospray ionization (ESI)-like' multiply charged ions for larger biomolecules, whilst maintaining the benefits of traditional MALDI including high tolerance to contaminants, low analyte consumption and rapid analysis. These and other advantages of liquid AP-MALDI MS have been explored in this study to investigate its potential in microbial biotyping. Methods Genetically diverse bacterial strains were analyzed using liquid AP-MALDI MS, including clinically relevant species such as Escherichia coli, Staphylococcus aureus and Klebsiella pneumoniae. Bacterial cultures were subjected to a simple and fast extraction protocol using ethanol and formic acid. Extracts were spotted with a liquid support matrix (LSM) and analyzed using a Synapt G2-Si mass spectrometer with an in-house built AP-MALDI source. Results Each species produces a unique lipid profile in the m/z range of 400-1100, allowing species discrimination. Traditional (solid) MALDI MS produced spectra containing a high abundance of matrix-related clusters and an absence of lipid peaks. The MS profiles of the bacterial species tested form distinct clusters using principle component analysis (PCA) with a classification accuracy of 98.63% using a PCA-based prediction model. Conclusions Liquid AP-MALDI MS profiles can be sufficient to distinguish clinically relevant bacterial pathogens and other bacteria, based on their unique lipid profiles. The analysis of the lipid MS profiles is typically excluded from commercial instruments approved for clinical diagnostics.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
12:57Isolation and Chemical Characterization of Lipid A from Gram-negative Bacteria
Published on: September 16, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...