Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Improving the Electrocatalytic Activity and Durability of the La<sub>0.6</sub>Sr<sub>0.4</sub>Co<sub>0.2</sub>Fe<sub>0.8</sub>O<sub>3-δ</sub> Cathode by Surface Modification.

ACS applied materials & interfaces·2018
Same author

Oriented electron transmission in polyoxometalate-metalloporphyrin organic framework for highly selective electroreduction of CO<sub>2</sub>.

Nature communications·2018
Same author

Immune Checkpoint Inhibition Overcomes ADCP-Induced Immunosuppression by Macrophages.

Cell·2018
Same author

Impact of Strain-Induced Changes in Defect Chemistry on Catalytic Activity of Nd<sub>2</sub>NiO<sub>4+δ</sub> Electrodes.

ACS applied materials & interfaces·2018
Same author

Curcumin induces apoptosis and inhibits angiogenesis in murine malignant mesothelioma.

International journal of oncology·2018
Same author

Deletion of SMARCA4 impairs alveolar epithelial type II cells proliferation and aggravates pulmonary fibrosis in mice.

Genes & diseases·2018
Same journal

[Study on <i>In Vitro</i> Chromosome Aberration Test for Nanomaterials and Medical Devices Containing Nanomaterials].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
Same journal

[Research on the Coordinated Mechanism of Medical Device Research and Evaluation in China and the United States].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
Same journal

[Research and Countermeasure Analysis on the Classification of Brain-Computer Interface Rehabilitation Medical Devices].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
Same journal

[Development of Portable Sleep Monitoring System].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
Same journal

[Design and Application of 3D-Printed Individualized Pelvic Prostheses].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
Same journal

[Study on Standardization Methods of Multi-Source Heterogeneous Data from ICU Medical Devices Based on openEHR].

Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation·2026
See all related articles

Related Experiment Video

Updated: Jan 1, 2026

Lensless Fluorescent Microscopy on a Chip
11:23

Lensless Fluorescent Microscopy on a Chip

Published on: August 17, 2011

18.1K

[Development of Immunofluorescence Reader Based on Microfluidic Chip].

Lei Wang1, Jiang Liu1, Zhichao Duan1

  • 1Tianjin Paipudaye Instrument Technology Co., Ltd., Tianjin, 300400.

Zhongguo Yi Liao Qi Xie Za Zhi = Chinese Journal of Medical Instrumentation
|December 20, 2019
PubMed
Summary
This summary is machine-generated.

This study details a new microfluidic immunofluorescence reader, achieving over 99% correlation with existing systems for precise PSA quantification in clinical samples.

Keywords:
immunofluorescencemicrofluidicquantitative test

More Related Videos

Fluorescence detection methods for microfluidic droplet platforms
14:16

Fluorescence detection methods for microfluidic droplet platforms

Published on: December 10, 2011

22.8K
A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells
15:41

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

Published on: October 15, 2013

15.4K

Related Experiment Videos

Last Updated: Jan 1, 2026

Lensless Fluorescent Microscopy on a Chip
11:23

Lensless Fluorescent Microscopy on a Chip

Published on: August 17, 2011

18.1K
Fluorescence detection methods for microfluidic droplet platforms
14:16

Fluorescence detection methods for microfluidic droplet platforms

Published on: December 10, 2011

22.8K
A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells
15:41

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

Published on: October 15, 2013

15.4K

Area of Science:

  • Biomedical Engineering
  • Analytical Chemistry
  • Immunotechnology

Background:

  • Microfluidic immunofluorescence assays offer sensitive detection but require reliable readers.
  • Developing cost-effective and accurate readers is crucial for point-of-care diagnostics.

Purpose of the Study:

  • To develop and validate a novel microfluidic immunofluorescence reader.
  • To assess the reader's performance using clinical samples.

Main Methods:

  • System design, optical path optimization, hardware integration, and software algorithm development (data filtering, peak detection).
  • Photoelectric sensor design and implementation.
  • Quantitative testing using clinical Prostate-Specific Antigen (PSA) standard samples.

Main Results:

  • The developed reader demonstrated high accuracy, with a correlation coefficient exceeding 99% compared to a commercial FREND reader.
  • Assay precision was confirmed, showing a coefficient of variation (CV) below 10%.

Conclusions:

  • The developed microfluidic immunofluorescence reader is a viable and accurate tool for quantitative analysis.
  • The reader shows excellent performance for clinical PSA detection, comparable to established systems.