Related Experiment Video
Updated: Jan 1, 2026

Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Interference of hemolysis, hyperlipidemia, and icterus on plasma infrared spectral profile
Valérie Untereiner1,2, Roselyne Garnotel1,3, Gérard Thiéfin1,4
1Université de Reims Champagne-Ardenne, BioSpecT EA7506, UFR de Pharmacie, 51097, Reims, France.
Abstract:
Recently, pre-analytical, analytical, and post-analytical issues have been addressed to implement biofluid FTIR spectroscopy as a novel diagnostic tool in the clinical setting. Although hemolysis, icterus, and hyperlipidemia are known to interfere with colorimetric and turbidimetric biochemical methods, there are no data on their impact on serum/plasma FTIR spectra. This study aimed at investigating the impact of hemoglobin, bilirubin, and triglycerides concentrations on plasma spectral analysis. Plasma samples with high concentrations of hemoglobin, conjugated bilirubin, or triglycerides were studied. To mimic the various concentrations observed in clinical setting, samples were diluted using normal plasma and analyzed using high-throughput FTIR spectroscopy. Hemolytic, icteric, and hyperlipidemic plasma spectra were compared with control plasma spectra. Unsupervised analysis of all spectra was performed using principal component analysis. The comparison between control and hemolytic plasmas did not show spectral differences in the range of hemoglobin concentrations observed in spurious or pathological hemolysis. By contrast, spectra from lipidemic plasmas had different spectral profiles compared with control plasma, exhibiting increased absorbance in lipid bands. Differences in the same spectral regions were observed in spectra from icteric plasma, which may be explained by the hyperlipidemia associated with cholestasis. PCA did not discriminate between control and hemolytic plasmas up to 1 g/L hemoglobin but confirmed the interference of bilirubin and triglycerides concentrations on spectral classification. Our results show that hemolysis does not have an impact on the plasma spectral profile except for high concentrations of hemoglobin rarely observed in clinical practice, whereas icterus and hyperlipidemia constitute significant confounding factors. Graphical abstract.
More Related Videos
11:05High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
10:50Detection and Quantification of Plasmodium falciparum in Aqueous Red Blood Cells by Attenuated Total Reflection Infrared Spectroscopy and Multivariate Data Analysis
Published on: November 2, 2018
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
IR Spectrometers
Atomic Emission Spectroscopy: Interference
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...