Interference of hemolysis, hyperlipidemia, and icterus on plasma infrared spectral profile

Valérie Untereiner1,2, Roselyne Garnotel1,3, Gérard Thiéfin1,4

  • 1Université de Reims Champagne-Ardenne, BioSpecT EA7506, UFR de Pharmacie, 51097, Reims, France.

Related Concept Videos

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.2K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.9K
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.1K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
551
Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
4.5K
IR Spectrum01:19

IR Spectrum

When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
1.9K