Related Experiment Video
Updated: Jan 1, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Use of flash glucose-sensing technology in patients with type 2 diabetes treated with liraglutide combined with CSII:
Ming-Yan Yao1,2, Li-Qin Li1, Jian-Xia Ma1
1Department of Endocrinology, The Third Hospital of Hebei Medical University, Shijiazhuang, China.
Abstract:
Glycemic variability (GV) may be linked to the development of diabetic complications by inducing inflammation, oxidative stress, and endothelial dysfunction. Flash glucose monitoring (FGM) provides a novel method of continuously monitoring interstitial glucose levels for up to 14 days. This study randomly assigned poorly controlled type 2 diabetes mellitus patients treated with metformin and multiple daily injections of insulin (n=60) to either continuous subcutaneous insulin infusion (CSII) treatment or CSII in combination with liraglutide (CSII+Lira) treatment for 14 days during hospitalization. GV was assessed using a FGM system; weight and cardiometabolic biomarkers were also evaluated. The coefficient of variation was significantly reduced in the CSII+Lira group (P<0.001), while no significant change was observed in the CSII group. The changes differed significantly between the two groups in mean amplitude of glycemic excursions (P=0.004), standard deviation (P=0.006), and the percentage of time in the target range (4-10 mmol/L, P=0.005 and >10 mmol/L, P=0.028). The changes in mean of daily differences, interquartile range, and percentage of time in hypoglycemia (<3.3 mmol/L) and hyperglycemia (>13.9 mmol/L) identified by FGM showed no difference. Treatment with liraglutide increased serum adiponectin [33.5 (3.5, 47.7) pg/mL, P=0.003] and heme oxygenase-1 levels [0.4 (-0.0, 1.8) ng/mL, P=0.001] and reduced serum leptin levels [-2.8 (3.9) pg/mL, P<0.001]. Adding the glucagon-like peptide-1 analog liraglutide improved GV, weight, and some cardiometabolic risk markers. The FGM system is, therefore, shown to be a novel and useful method for glucose monitoring.
Related Concept Videos
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by...
Oral Hypoglycemic Agents: Glinides
Dipeptidyl Peptidase 4 Inhibitors
Diabetes Mellitus: Type 2 and Gestational
Oral Hypoglycemic Agents: Biguanides and Glitazones
Hypoglycemia and Glucagon

