Related Experiment Video
Updated: Jan 1, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Assessment of Extubation Readiness Using Spontaneous Breathing Trials in Extremely Preterm Neonates
Wissam Shalish1, Lara Kanbar2, Lajos Kovacs3
1Division of Neonatology, Department of Pediatrics, Montreal Children's Hospital, McGill University Health Center, Montreal, Quebec, Canada.
Importance:
Spontaneous breathing trials (SBTs) are used to determine extubation readiness in extremely preterm neonates (gestational age ≤28 weeks), but these trials rely on empirical combinations of clinical events during endotracheal continuous positive airway pressure (ET-CPAP).
Objectives:
To describe clinical events during ET-CPAP and to assess accuracy of comprehensive clinical event combinations in predicting successful extubation compared with clinical judgment alone.
Design, Setting, And Participants:
This multicenter diagnostic study used data from 259 neonates seen at 5 neonatal intensive care units from the prospective Automated Prediction of Extubation Readiness (APEX) study from September 1, 2013, through August 31, 2018. Neonates with birth weight less than 1250 g who required mechanical ventilation were eligible. Neonates deemed to be ready for extubation and who underwent ET-CPAP before extubation were included.
Interventions:
In the APEX study, cardiorespiratory signals were recorded during 5-minute ET-CPAP, and signs of clinical instability were monitored.
Main Outcomes And Measures:
Four clinical events were documented during ET-CPAP: apnea requiring stimulation, presence and cumulative durations of bradycardia and desaturation, and increased supplemental oxygen. Clinical event occurrence was assessed and compared between extubation pass and fail (defined as reintubation within 7 days). An automated algorithm was developed to generate SBT definitions using all clinical event combinations and to compute diagnostic accuracies of an SBT in predicting extubation success.
Results:
Of 259 neonates (139 [54%] male) with a median gestational age of 26.1 weeks (interquartile range [IQR], 24.9-27.4 weeks) and median birth weight of 830 g (IQR, 690-1019 g), 147 (57%) had at least 1 clinical event during ET-CPAP. Apneas occurred in 10% (26 of 259) of neonates, bradycardias in 19% (48), desaturations in 53% (138), and increased oxygen needs in 41% (107). Neonates with successful extubation (71% [184 of 259]) had significantly fewer clinical events (51% [93 of 184] vs 72% [54 of 75], P = .002), shorter cumulative bradycardia duration (median, 0 seconds [IQR, 0 seconds] vs 0 seconds [IQR, 0-9 seconds], P < .001), shorter cumulative desaturation duration (median, 0 seconds [IQR, 0-59 seconds] vs 25 seconds [IQR, 0-90 seconds], P = .003), and less increase in oxygen (median, 0% [IQR, 0%-6%] vs 5% [0%-18%], P < .001) compared with neonates with failed extubation. In total, 41 602 SBT definitions were generated, demonstrating sensitivities of 51% to 100% (median, 96%) and specificities of 0% to 72% (median, 22%). Youden indices for all SBTs ranged from 0 to 0.32 (median, 0.17), suggesting low accuracy. The SBT with highest Youden index defined SBT pass as having no apnea (with desaturation requiring stimulation) or increase in oxygen requirements by 15% from baseline and predicted extubation success with a sensitivity of 93% and a specificity of 39%.
Conclusions And Relevance:
The findings suggest that extremely preterm neonates commonly show signs of clinical instability during ET-CPAP and that the accuracy of multiple clinical event combinations to define SBTs is low. Thus, SBTs may provide little added value in the assessment of extubation readiness.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: