Ethylene Oxide Exposure Attribution and Emissions Quantification Based on Ambient Air Measurements near a
Eduardo P Olaguer1, Amy Robinson1, Susan Kilmer1
1Michigan Department of Environment, Great Lakes, and Energy, Lansing, MI 48909, USA.
Abstract:
Ethylene oxide (EtO) is a known carcinogen and mutagen associated with increased incidence of breast and blood cancers. The largest medical sterilization facility in Michigan had been assessed by the U.S. Environmental Protection Agency as imposing an additional cancer risk greater than one in one thousand in nearby neighborhoods. This prompted the Michigan Department of Environmental Quality (now referred to as the Department of Environment, Great Lakes, and Energy) to conduct an air quality modeling study of the ambient EtO impacts of the sterilization facility, followed by 24 h Summa canister sampling and TO-15 analysis in two phases. Inverse modeling of the measured 24 h EtO concentrations during the second phase yielded estimates of 594 lbs/year for the facility's total emissions of EtO and 0.247 µg/m3 for the urban background concentration. The inverse-modeled emissions are similar to reported emissions by the facility operator based on indoor air measurements and simple mass balance assumptions, while the inferred background concentration agrees with estimates from other field investigations. The estimated peak 24 h exposure to EtO caused by the sterilization facility in nearby neighborhoods was 1.83 μg/m3 above the background level, corresponding to an additional cancer risk of approximately one in one hundred, if assumed to represent annual mean exposure.
More Related Videos
08:23Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Autoxidation of Ethers to Peroxides and Hydroperoxides
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Oxygen Requirements and Growth Patterns
Hess's Law