Related Experiment Video
Updated: Jan 1, 2026

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Usefulness of dictionary learning-based processing for improving image quality of sub-millisievert low-dose chest CT:
Yoshinori Kanii1, Yasutaka Ichikawa2, Ryohei Nakayama3
1Department of Radiology, Mie University Hospital, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan.
Purpose:
To develop a dictionary learning (DL)-based processing technique for improving the image quality of sub-millisievert chest computed tomography (CT).
Materials And Methods:
Standard-dose and sub-millisievert chest CT were acquired in 12 patients. Dictionaries including standard- and low-dose image patches were generated from the CT datasets. For each patient, DL-based processing was performed for low-dose CT using the dictionaries generated from the remaining 11 patients. This procedure was repeated for all 12 patients. Image quality of normal thoracic structures on the processed sub-millisievert CT images was assessed with a 5-point scale (5 = excellent, 1 = very poor). Lung lesion conspicuity was also assessed on a 5-point scale.
Results:
Image noise on sub-millisievert CT was significantly decreased with DL-based image processing (48.5 ± 13.7 HU vs 20.4 ± 7.9 HU, p = 0.0005). Image quality of lung structures was significantly improved with DL-based method (middle level of lung, 2.25 ± 0.75 vs 2.92 ± 0.79, p = 0.0078). Lung lesion conspicuity was also significantly improved with DL-based technique (solid nodules, 3.4 ± 0.6 vs 2.7 ± 0.6, p = 0.0273).
Conclusion:
Image quality and lesion conspicuity on sub-millisievert chest CT images may be improved by DL-based post-processing.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography