Comparative evaluation of four suspended particulate matter (SPM) sampling devices and their use for monitoring SPM
Sabine Keßler1,2, Thorsten Pohlert3, Vera Breitung3
1Department of Hydrology, Trier University, 54286, Trier, Germany. kessler@ibla.lu.
Abstract:
Representative sampling of suspended particulate matter is fundamental for assessing river sediment quality, including the distribution and physicochemical characterisation of particles at different hydrological events. This study compares time-integrated samplers and discrete sampling methods, focusing on (a) the representativeness of the different methods and (b) the comparability between the various sampling techniques. The study investigates whether different sampling devices used under the same conditions can reproduce the annual mean. Two time-integrated sampling techniques (Binnensammler floating collector (BS); self-constructed Phillips sampler (PS)) and two discrete sampling systems (continuous-flow centrifuge (CFC); hydrocyclone (HC)) were compared. The monitoring program (August 2013 to August 2014) was conducted using a 4-week sampling frequency at two different monitoring stations in the Rhine river basin. The analysis of physicochemical parameters included total organic carbon (TOC), particulate phosphorus (PP), grain size distribution (GSD), metals, and organic pollutants (PCBs, HCB, PAH). A nested analysis of variance (ANOVA) was used to evaluate the dependence of suspended matter quality parameters on the sampling method, the sampling device, and the sampling station. According to ANOVA, physical and chemical parameters as well as persistent organic pollutants are homogenous for the time-integrated samplers PS and BS. Comparing PS and the reference technique CFC, only the mean annual concentration of TOC is significantly higher for CFC (5.91%; PS, 4.53%) due to degradation processes. With the exception of TOC, Ni, and GSD, data of BS was comparable with that of CFC. Comparing CFC and HC, there are significant differences for GSD, Zn, and Ni. An analysis of the time series of GSD < 63 μm and sum of PAHs confirms the findings of the nested ANOVA, showing that HC time series display significant differences compared with the other samplers.
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...