Related Experiment Video
Updated: Jan 1, 2026

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Intraoperative Ultrasound Guidance for Banding of an Arteriovenous Fistula Causing High Cardiac Output Heart Failure
Anthony D Turner1, Michael Chen2, Neera Dahl3
1Division of Vascular Surgery, Department of Surgery, Yale School of Medicine, New Haven, CT.
Abstract:
The creation of an arteriovenous fistula (AVF) is the preferred mode of access for hemodialysis in patients with End-Stage Renal Disease (ESRD). High output cardiac failure is a known but rare complication of AVF resulting from high flow volume. This case report describes the use of intraoperative ultrasound as a guide for the banding of an AVF to decrease flow volume in a patient with high cardiac output failure. The access was preserved, and a gradual decline of cardiac function before and recovery after banding is demonstrated over an 18-year period.
Related Concept Videos
Aneurysm IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management