Related Experiment Video
Updated: Jan 1, 2026

Preparation of Drosophila Larval Samples for Gas Chromatography-Mass Spectrometry GC-MS-based Metabolomics
Published on: June 6, 2018
A comprehensive automatic data analysis strategy for gas chromatography-mass spectrometry based untargeted
Yu-Ying Zhang1, Qian Zhang1, Yue-Ming Zhang2
1College of Pharmacy, Ningxia Medical University, Yinchuan 750004, China; Key Laboratory of Hui Ethnic Medicine Modernization Ministry of Education, Ningxia Medical University, Yinchuan 750004, China.
Abstract:
Automatic data analysis for gas chromatography-mass spectrometry (GC-MS) is a challenging task in untargeted metabolomics. In this work, we provide a novel comprehensive data analysis strategy for GC-MS-based untargeted metabolomics (autoGCMSDataAnal) by developing a new automatic strategy for performing TIC peak detection and resolution and proposing a novel time-shift correction and component registration algorithm. autoGCMSDataAnal uses original acquired GC-MS datafiles as input to automatically perform TIC peak detection, component resolution, time-shift correction and component registration, statistical analysis, and compound identification. We utilize standards and complex plant samples to comprehensively investigate the performance of autoGCMSDataAnal. The results suggest that the developed strategy is comparable with several state-of-the-art methods that are widely used in GC-MS-based untargeted metabolomics. Based on the proposed strategy, we develop a user-friendly MATLAB GUI for users who are unfamiliar with programming languages to facilitate their routine analysis, which can be freely downloaded at: http://software.tobaccodb.org/software/autogcmsdataanal.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry